BMC Mainview for z/OS Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.
Overview
Finding ID | Version | Rule ID | IA Controls | Severity |
V-224611 | ZMVZT032 | SV-224611r958482_rule | Medium |
Description |
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data. |
STIG | Date |
z/OS BMC MAINVIEW for z/OS for TSS Security Technical Implementation Guide | 2025-02-24 |
Details
Check Text (C-26294r519010_chk) |
Refer to the following report produced by the TSS Data Collection: - TSSCMDS.RPT(#STC) Automated Analysis Refer to the following report produced by the TSS Data Collection: - PDI(ZMVZ0032) Verify that the BMC Mainview for z/OS started task(s) is (are) defined in the TSS STC record. |
Fix Text (F-26282r519011_fix) |
The BMC Mainview for z/OS system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP. A unique ACID must be assigned for the BMC Mainview for z/OS started task(s) thru a corresponding STC table entry. The following sample set of commands is shown here as a guideline: TSS ADD(STC) PROCNAME(MV$CAS) ACID(MV$CAS) TSS ADD(STC) PROCNAME(MV$MVS) ACID(MV$MVS) |