TOSS must disable network management of the chrony daemon.
Overview
Finding ID
Version
Rule ID
IA Controls
Severity
V-253073
TOSS-04-040180
SV-253073r958478_rule
Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time when a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.
Not exposing the management interface of the chrony daemon on the network diminishes the attack space.
TOSS utilizes the "timedatectl" command to view the status of the "systemd-timesyncd.service." The "timedatectl" status will display the local time, UTC, and the offset from UTC.
Note that USNO offers authenticated NTP service to DoD and U.S. Government agencies operating on the NIPR and SIPR networks. Visit https://www.usno.navy.mil/USNO/time/ntp/dod-customers for more information.