The RUCKUS ICX device must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Overview

Finding ID Version Rule ID IA Controls Severity
V-273821 RCKS-NDM-000680 SV-273821r1111025_rule   Medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of GMT, or local time with an offset from UTC.
STIG Date
RUCKUS ICX NDM Security Technical Implementation Guide 2025-05-28

Details

Check Text (C-77912r1111023_chk)
Verify a time zone is configured on the device:

SSH@ICX# show clock
15:13:51.679 GMT+00 Mon Jan 15 2024

If the time does not reflect a time zone that can be mapped to GMT, this is a finding.
Fix Text (F-77817r1111024_fix)
Configure a time zone as needed:

SSH@ICX(config) clock timezone [timezone]