The Palo Alto Networks security platform must have alarms enabled.
Overview
Finding ID | Version | Rule ID | IA Controls | Severity |
V-228662 | PANW-NM-000097 | SV-228662r997675_rule | Low |
Description |
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less). |
STIG | Date |
Palo Alto Networks NDM Security Technical Implementation Guide | 2025-03-12 |
Details
Check Text (C-30897r997673_chk) |
Go to Device >> Log Settings >> Alarms. If the "Enable Alarms" box is not checked, this is a finding. |
Fix Text (F-30874r997674_fix) |
Go to Device >> Log Settings >> Alarms. Select the "Edit" icon (the gear symbol in the upper-right corner of the pane). In the "Alarm Settings" window; select the "Enable Alarms" box. Select "OK". Commit changes by selecting "Commit" in the upper-right corner of the screen. Select "OK" when the confirmation dialog appears. |