DISA STIGS Viewer

The Okta Dashboard application must be configured to use multifactor authentication.

Overview

Finding ID Version Rule ID IA Controls Severity
V-273194 OKTA-APP-000570 SV-273194r1098849_rule   High
Description
To ensure accountability and prevent unauthenticated access, nonprivileged users must use multifactor authentication to prevent potential misuse and compromise of the system. Multifactor authentication uses two or more factors to achieve authentication. Factors include: (i) Something you know (e.g., password/PIN); (ii) Something you have (e.g., cryptographic identification device, token); or (iii) Something you are (e.g., biometric). A nonprivileged account is any information system account with authorizations of a nonprivileged user. Network access is any access to an application by a user (or process acting on behalf of a user) where the access is obtained through a network connection. Applications integrating with the DOD Active Directory and using the DOD CAC are examples of compliant multifactor authentication solutions. Satisfies: SRG-APP-000150, SRG-APP-000155
STIG Date
Okta Identity as a Service (IDaaS) Security Technical Implementation Guide 2025-05-06

Details

Check Text (C-77285r1098847_chk)
From the Admin Console:
1. Go to Security >> Authentication Policies.
2. Click the "Okta Dashboard" policy.
3. Click the "Actions" button next to the top rule and select "Edit".
4. In the "User must authenticate with" field, verify that either "Password/IdP + Another factor" or "Any 2 factor types" is selected.

If either of these settings is incorrect, this is a finding.
Fix Text (F-77190r1098848_fix)
From the Admin Console:
1. Go to Security >> Authentication Policies.
2. Click the "Okta Dashboard" policy.
3. Click the "Actions" button next to the top rule and select "Edit".
4. In the "User must authenticate with" field, select either "Password/IdP + Another factor" or "Any 2 factor types".