The Juniper SRX Services Gateway must record time stamps for log records using Coordinated Universal Time (UTC).
Overview
Finding ID | Version | Rule ID | IA Controls | Severity |
V-223201 | JUSX-DM-000065 | SV-223201r961443_rule | Medium |
Description |
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. UTC is normally used in DoD; however, Greenwich Mean Time (GMT) may be used if needed for mission requirements. |
STIG | Date |
Juniper SRX Services Gateway NDM Security Technical Implementation Guide | 2024-12-20 |
Details
Check Text (C-24874r513290_chk) |
Verify the time zone is set to UTC. [edit] show system time-zone If the time zone is not set to UTC, this is a finding. |
Fix Text (F-24862r513291_fix) |
The following command sets the time zone to UTC. [edit] set system time-zone UTC |