DISA STIGS Viewer

Sentry must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes.

Overview

Finding ID Version Rule ID IA Controls Severity
V-250986 MOIS-ND-000140 SV-250986r1028213_rule   Low
Description
By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.
STIG Date
Ivanti Sentry 9.x NDM Security Technical Implementation Guide 2024-09-25

Details

Check Text (C-54421r1004833_chk)
Review Sentry configuration to verify that it enforces the limit of three consecutive invalid logon attempts.

1. Log in to Sentry System Manager portal.
2. Go to the "Security" tab.
3. Go to "Password Policy".
4. Look for "Number of Failed Attempts" and determine if the value is set to 3. If it is not, this is a finding.
5. Verify the Auto-Lock Time value is set to 900 seconds or more.

If the Auto-Lock Time is not set to 900 seconds or more, this is a finding.
Fix Text (F-54375r1004834_fix)
Configure Sentry to enforce the limit of three consecutive invalid login attempts during a 15-minute time period.

1. Log in to Sentry System Manager portal.
2. Go to the "Security" tab.
3. Go to "Password Policy".
4. For "Number of Failed Attempts", set value to 3.
5. For "Auto-Lock Time", set value to 900 seconds or more.