The HP FlexFabric Switch must generate an immediate real-time alert of all audit failure events requiring real-time alerts.
Overview
Finding ID | Version | Rule ID | IA Controls | Severity |
V-217464 | HFFS-ND-000097 | SV-217464r961401_rule | Medium |
Description |
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less). |
STIG | Date |
HP FlexFabric Switch NDM Security Technical Implementation Guide | 2025-06-12 |
Details
Check Text (C-18688r293067_chk) |
Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time. [HP] display info-center Information Center: Enabled Console: Enabled Monitor: Enabled Log host: Enabled 192.100.50.27, port number: 514, host facility: local7 Log buffer: Enabled Max buffer size 1024, current buffer size 512 Current messages 66, dropped messages 0, overwritten messages 0 Log file: Enabled Security log file: Enabled Information timestamp format: Log host: Date Other output destination: Date If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding. |
Fix Text (F-18686r293068_fix) |
Configure the HP FlexFabric Switch to generate an immediate real-time alert of all audit failure events requiring real-time alerts. [HP] info-center enable |