The HP FlexFabric Switch must initiate session auditing upon startup.
Overview
Finding ID | Version | Rule ID | IA Controls | Severity |
V-217439 | HFFS-ND-000025 | SV-217439r960888_rule | Low |
Description |
If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created. |
STIG | Date |
HP FlexFabric Switch NDM Security Technical Implementation Guide | 2025-06-12 |
Details
Check Text (C-18663r292992_chk) |
Determine if the info-center feature is enabled on the HP FlexFabric Switch: [HP] display info-center Information Center: Enabled If logging is not enabled, this is a finding. |
Fix Text (F-18661r292993_fix) |
Enable info-center feature on the HP FlexFabric Switch: [HP] info-center enable Note: By default, the information center is enabled. |