DISA STIGS Viewer

The Dell OS10 Switch must implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

Overview

Finding ID Version Rule ID IA Controls Severity
V-269972 OS10-L2S-000300 SV-269972r1052302_rule   Medium
Description
Separating critical system components and functions from other noncritical system components and functions through separate subnetworks may be necessary to reduce susceptibility to a catastrophic or debilitating breach or compromise that results in system failure. For example, physically separating the command-and-control function from the in-flight entertainment function through separate subnetworks in a commercial aircraft provides an increased level of assurance in the trustworthiness of critical system functions. Satisfies: SRG-NET-000715-L2S-000120, SRG-NET-000512-L2S-000012
STIG Date
Dell OS10 Switch Layer 2 Switch Security Technical Implementation Guide 2024-12-11

Details

Check Text (C-74005r1052300_chk)
Review the switch configurations and verify that no access switch ports have been assigned membership to the default VLAN (i.e., VLAN 1). VLAN assignments can be verified via the “show vlan” command:

OS10# show vlan
Codes: * - Default VLAN, M - Management VLAN, R - Remote Port Mirroring VLANs,
@ - Attached to Virtual Network, P - Primary, C - Community, I - Isolated,
S - VLAN-Stack VLAN
Q: A - Access (Untagged), T - Tagged
NUM Status Description Q Ports
* 1 Inactive
30 Inactive Management VLAN
100 Inactive A Eth1/1/1
200 Inactive A Eth1/1/3-1/1/58
201 Inactive A Eth1/1/2
OS10#

If there are access switch ports assigned to the default VLAN, this is a finding.
Fix Text (F-73906r1052301_fix)
Remove the assignment of the default VLAN from all access switch ports:

OS10(config)# interface range eth1/1/4-1/1/58
OS10(conf-range-eth1/1/4-1/1/58)# switchport mode access
OS10(conf-range-eth1/1/4-1/1/58)# switchport access vlan 200