The Cisco switch must be configured to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.
Overview
Finding ID
Version
Rule ID
IA Controls
Severity
V-220547
CISC-ND-000980
SV-220547r961392_rule
Medium
Description
In order to ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able to allocate audit record storage capacity. The task of allocating audit record storage capacity is usually performed during initial device setup if it is modifiable.
The value for the organization-defined audit record storage requirement will depend on the amount of storage available on the network device, the anticipated volume of logs, the frequency of transfer from the network device to centralized log servers, and other factors.
Verify that the Cisco switch is configured with a logging buffer size. The configuration should look like the example below:
logging buffered xxxxxxxx informational
If a logging buffer size is not configured, this is a finding.
If the Cisco switch is not configured to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements, this is a finding.
Fix Text (F-22251r508586_fix)
Configure the buffer size for logging as shown in the example below: