CylanceON-PREM must be configured to send alerts via Simple Mail Transfer Protocol (SMTP).
Overview
Finding ID | Version | Rule ID | IA Controls | Severity |
V-272634 | CYLN-OP-000560 | SV-272634r1113494_rule | Medium |
Description |
Failure to notify personnel of failed tests introduces a risk to the system. Corrective action and the unsecure condition(s) will remain. Satisfies: SRG-APP-000275, SRG-APP-000279, SRG-APP-000940 |
STIG | Date |
Arctic Wolf CylanceON-PREM Security Technical Implementation Guide | 2025-06-11 |
Details
Check Text (C-76715r1113492_chk) |
Verify SMTP Settings. Administrator privileges are required. 1. Log in to the admin console. 2. Navigate to CONFIGURATION >> Settings. 3. Find SMTP. If SMTP is not enabled, this is a finding. If SMTP settings are not populated and event type notifications not enabled, this is a finding. |
Fix Text (F-76620r1113493_fix) |
Configure SMTP Settings. Administrator privileges are required. 1. Log in to the admin console. 2. Navigate to CONFIGURATION >> Settings. 3. Find SMTP and click on the edit button. 4. Slide the button to enable. 5. Populate the Syslog/SIEM configuration. 6. Click the green check to save. |